Two-layer Medium Ultrasonic Phased Array Total Focusing Method Imaging Based on Sparse Matrix

  • HU Hongwei ,
  • DU Jian ,
  • LI Yang ,
  • ZHOU Zhenggan
Expand
  • 1. School of Automotive and Mechanical Engineering, Changsha University of Science and Technology, Changsha 410114;
    2. School of Mechanical Engineering and Automation, Beihang University, Beijing 100191

Received date: 2016-07-25

  Revised date: 2016-12-14

  Online published: 2017-07-20

Abstract

Ultrasonic phased array total focusing method has the advantages of high accuracy and dynamic focusing in all regions, but the problem of long imaging time limits of the actual industrial application. In order to improve the imaging efficiency of phased array total focusing method, taking commonly used wedge coupling detection for example, the delay time of all array elements are calculated in two-layer medium based on Fermat principle, a two-layer medium phased array total focusing method is built. By reducing the number of transmitting/receiving elements, with the same effective aperture as the whole array, the weighting function of transmitting/receiving elements distribution is studied, and a two-layer medium corrected sparse total focusing method is proposed. Taking the side-drilled holes with arc distribution for example, two images of total focusing method and sparse total focusing method in the two-layer medium are formed, and the effects on defect quantitative precision and calculation efficiency are discussed when the transmitter array is sparse. The results show that the corrected sparse total focusing method can improve the imaging efficiency obviously in the meanwhile the imaging accuracy is kept. For a 32-element transducer, when the number of the sparse transmitting elements reaches 8, the error between sparse matrix and full matrix is less than 5.2%, while the computational efficiency is nearly fourfold improved.

Cite this article

HU Hongwei , DU Jian , LI Yang , ZHOU Zhenggan . Two-layer Medium Ultrasonic Phased Array Total Focusing Method Imaging Based on Sparse Matrix[J]. Journal of Mechanical Engineering, 2017 , 53(14) : 128 -135 . DOI: 10.3901/JME.2017.14.128

References

[1] 林莉,杨平华,张东辉,等. 厚壁铸造奥氏体不锈钢管道焊缝超声相控阵检测技术概述[J]. 机械工程学报,2012,48(4):12-20. LIN Li,YANG Pinghua,ZHANG Donghui,et al. Review of phased array ultrasonic testing for thick wall cast austenitic stainless steel pipeline welds[J]. Journal of Mechanical Engineering,2012,48(4):12-20.
[2] 靳世久,杨晓霞,陈世利,等. 超声相控阵检测技术的发展及应用[J]. 电子测量与仪器学报,2014,28(9):925-934 JIN Shijiu,YANG Xiaoxia,CHEN Shili,et al. Development and application of ultrasonic phased array inspection technology[J]. Journal of Electronic Measurement and Instrumentation,2014,28(9):925-934.
[3] ZHANG J,DRINKWATER B W,WILCOX P D. Effects of array transducer inconsistencies on total focusing method imaging performance[J]. NDT & E International,2011,44(4):361-368.
[4] VERKOOIJEN J,BOULAVINOV A. Sampling phased array a new technique for ultrasonic signal processing and imaging[J]. Insight-Non-Destructive Testing and Condition Monitoring,2008,50(3):153-157.
[5] 周正干,李洋,周文彬. 相控阵超声后处理成像技术研究、应用和发展[J]. 机械工程学报,2016,52(6):1-11. ZHOU Zhenggan,LI Yang,ZHOU Wenbin. Ultrasonic phased array post-processing imaging techniques:A review[J]. Journal of Mechanical Engineering,2016,52(6):1-11.
[6] HOLMES C,DRINKWATER B W,WILCOX P D. Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation[J]. NDT & E International,2005,38(8):701-711.
[7] BULAVINOV A,DALICHOW M,KRÖNING M,et al. Quantitative ultrasonic testing of pressurized components using sampling phased array[C]//National Seminar on Non-Destructive Evaluation,Hyderabad,2006:437-449.
[8] RUSSELL J,LONG R,DUXBURY D,et al. Development and implementation of a membrane-coupled conformable array transducer for use in the nuclear industry[J]. Insight-Non-Destructive Testing and Condition Monitoring,2012,54(7):386-393.
[9] LI C,PAIN D,WILCOX P D,et al. Imaging composite material using ultrasonic arrays[J]. NDT & E International,2013,53:8-17.
[10] SUTCLIFFE M,WESTON M,DUTTON B,et al. Real-time full matrix capture for ultrasonic non-destructive testing with acceleration of post-processing through graphic hardware[J]. NDT & E International,2012,51:16-23.
[11] NJIKI M,ELOUARDI A,BOUAZIZ S,et al. A real-time implementation of the total focusing method for rapid and precise diagnostic in nondestructive evaluation[C]//2013 IEEE 24th International Conference on Application Specific Systems,Architectures and Processors. IEEE,2013:245-248.
[12] HUNTER A J,DRINKWATER B W,WILCOX P D. The wavenumber algorithm for full-matrix imaging using an ultrasonic array[J]. Ultrasonics,Ferroelectrics,and Frequency Control,IEEE Transactions on,2008,55(11):2450-2462.
[13] CARCREFF E,BRACONNIER D. Comparison of conventional technique and migration approach for total focusing[J]. Physics Procedia,2015,70:566-569.
[14] 施克仁,郭寓岷. 相控阵超声成像检测[M]. 北京:高等教育出版社,2010. SHI Keren,GUO Yumin. Phased array ultrasonic imaging and testing[M]. Beijing:Higher Education Press,2010.
[15] PENG H,PENG J,ZHU H,et al. The efficiency optimization of full matrix capture imaging detection based on increasing the effective aperture[C]//Nondestructive Evaluation/Testing (FENDT),2014 IEEE Far East Forum on. IEEE,2014:50-56.
[16] 周正干,彭地,李洋,等. 相控阵超声检测技术中的全聚焦成像算法及其校准研究[J]. 机械工程学报,2015,51(10):1-7. ZHOU Zhenggan,PENG Di,LI Yang,et al. Ultrasonic phased array inspection on the wedge using full matrix data[J]. Journal of Mechanical Engineering,2015,51(10):1-7.
[17] LOCKWOOD G R,LI P C,O'DONNELL M,et al. Optimizing the radiation pattern of sparse periodic linear arrays[J]. IEEE Transactions on Ultrasonics,Ferroelectrics,and Frequency Control,1996,43(1):7-14.
[18] SHIN H C,PRAGER R,NG J,et al. Sensitivity to point-spread function parameters in medical ultrasound image deconvolution[J]. Ultrasonics,2009,49(3):344-357.
[19] MOREAU L,DRINKWATER B W,WILCOX P D. Ultrasonic imaging algorithms with limited transmission cycles for rapid nondestructive evaluation[J]. IEEE Transactions on Ultrasonics,Ferroelectrics,and Frequency Control,2009,56(9):1932-1944.
[20] NIKOLOV M,BEHAR V. Analysis and optimization of medical ultrasound imaging using the effective aperture approach[J]. Cybernetics and Information Technologies,2005,5(2):53-68.