The two-phase mass flow coefficient is proposed to correct the deviation of the V-Cone meter when it is used to measure the wet gas. The effects of the Lockhart-Martinelli parameter, the gas densiometric Froude number and the gas to liquid density ratio on the two-phase flow coefficient are experimentally investigated. The diameter ratio of the V-Cone meter is 0.55. The experimental fluids are air and tap water. The gas to liquid density ratio, the gas densiometric Froude number and the Lockhart-Martinelli parameter range from 0.002 445 to 0.006 083, from 0.3 to 2.0 and from 0.01 to 0.34, respectively. The results show that the two-phase mass flow coefficient linearly increases with the Lockhart-Martinelli parameter and is affected by the gas densiometric Froude number and the gas to liquid density ratio. Then the quantitative relationship between the two-phase mass flow coefficient and the Lockhart-Martinelli parameter, the gas densiometric Froude number and the gas to liquid density ratio is obtained, based on which the correlation for the wet gas flow measurement is developed. The differential pressure response of the front and back cone of the V-Cone to the wet gas is investigated and the parameters affecting the different responses are also discussed, and finally the wet gas correlation to meter the gas and liquid mass flow rate is concluded. In the present cases, the relative error of the gas mass flow rate predicted by the correlation is within ±5.0% and the average relative error is 2.2%; the relative error of the liquid mass flow rate predicted by the correlation is within ±20.0% and the average relative error is 9.8%. The method proposed in this study possesses some remarkable performances, including simple structure, low cost and high accuracy.
HE Denghui
,
ZHANG Feng
,
CAO Honggui
,
YANG Yuanyuan
,
BAI Bofeng
. Online Measurement of Gas and Liquid Flow Rate in Wet Gas Base on Single V-cone Throttle[J]. Journal of Mechanical Engineering, 2016
, 52(8)
: 191
-197
.
DOI: 10.3901/JME.2016.08.191
[1] ASME. Wet gas flowmetering guideline,MFC-19G-2008[R]. New York:The American Society of Mechanical Engineers,2008.
[2] FALCONE G,HEWITT G F,ALIMONTI C. Multiphase flow metering[J]. Developments in Petroleum Science,2009,54:229-237.
[3] NFOGM. Handbook of Multiphase flow metering (Revision 2)[M]. 2nd ed. Norwegian:The Norwegian Society for Oil and Gas Measurement,2005.
[4] LAWRENCE P A. Wet gas measurement[C]//84th International School of Hydrocarbon Measurement,May 12-14,2009,Oklahoma City,OK,USA. 2009:165-179.
[5] MURDOCK J W. Two-phase flow measurements with orifices[J]. Journal of Basic Engineering,1962,84(4):419-433.
[6] JAMES R. Metering of steam-water two-phase flow by sharp-edged orifices[J]. Process Instrumentation for Mechanical Engineers,1965,180(23):549-566.
[7] SMITH R V,LEANG J T. Evaluation of correlations for two-phase flowmeters:Three current-one new[J]. Journal of Engineering for Power,1975,97(4):589-594.
[8] CHISHOLM D. Research note:Two-phase flow through sharp-edged orifices[J]. Journal Mechanical Engineering Science,1977,19(3):128-130.
[9] LIN Z H. Two-phase flow measurements with sharp-edged orifices[J]. International Journal of Multiphase Flow,1982,8(6):683-693.
[10] de LEEUW R. Liquid correction of Venturi meter readings in wet gas flow[C]//Proceedings of the 1997 North Sea Flow Measurement Workshop,London,UK:Energy Institute,1998:153-161.
[11] STEVEN R N. Wet gas metering with a horizontally mounted Venturi meter[J]. Journal of Flow Measurement and Instrumentation,2002,12(5):361-372.
[12] STEVEN R N. Horizontally installed cone differential pressure meter wet gas flow performance[J]. Flow Measurement and Instrumentation,2009,20(4-5):152-167.
[13] HE D,BAI B,XU Y,et al. A new model for the V-Cone meter in low pressure wet gas metering[J]. Measurement Science and Technology,2012,23(12):125305.1- 125305.9.
[14] LI Y,WANG J,GENG Y. Study on wet gas online flow rate measurement based on dual slotted orifice plate[J]. Flow Measurement and Instrumentation,2009,20(4-5):168-173.
[15] ZHANG F,DONG F,TAN C. High GVF and low pressure gas-liquid two-phase flow measurement based on dual-cone flowmeter[J]. Flow Measurement and Instrumentation,2010,21(3):410-417.
[16] 徐英,袁超,龙征海,等. 基于双节流装置的湿气测量方法[J]. 机械工程学报,2012,48(22):139-147.
XU Ying,YUAN Chao,LONG Zhenghai,et al. Wet gas measurement based on dual-throttle device[J]. Journal of Mechanical Engineering,2012,48(22):139-147.
[17] 贺登辉,鲁斌,李星,等. 双差压式湿气流量在线测量新方法研究[J]. 工程热物理学报,2013,34(5):878-882.
HE Denghui,LU Bin,LI Xing,et al. A new model to meter wet gas flow based on double differential pressure[J]. Journal of Engineering Thermophsics,2013,34(5):878-882.
[18] AGAR J,FARCHY D. Wet gas metering using dissimilar flow sensors:Theory and field trial results[C]//Society of Petroleum Engineers Annual Technical Conference and Exhibition 2002:San Antonio,Texas:SPE 77349.
[19] ISA. Dualstream 2 Advanced-Topside[EB/OL]. [2015-12-07]. http://www.solartronisa.com/Products/dualstream2.aspx.
[20] ØYSTEIN L B,EBBE N,LØLAND T,et al. New compact wet gas meter based on a microwave water
detection technique and differential pressure flow measurement[C/CD]//North Sea Flow Measurement Workshop,October 22-25,2002,St. Andrews,Scotland,UK.
[21] STEWART D G,HODGES D,BROWN G J. Recent research results in wet gas flow[C/CD]//3rd South East Asia Hydrocarbon Flow Measurement Workshop 2004,March 09-11,2004,St. Andrews:UK.
[22] 徐英,于中伟,张涛,等. V形内锥流量计关键参数对流出系数的影响[J]. 机械工程学报,2008,44(12):105-123.
XU Ying,YU Zhongwei,ZHANG Tao,et al. Influence of key factors on discharge coefficient in V-cone flowmeter[J]. Chinese Journal of Mechanical Engineering,2008,44(12):105-123.
[23] HE D H,BAI B F,Two-phase mass flow coefficient of V-Cone throttle device[J]. Experimental Thermal and Fluid Science,2014,57:77-85.
[24] MANDHANE J,GREGORY G,AZIZ K. A flow pattern map for gas-liquid flow in horizontal pipes[J]. International Journal of Multiphase Flow,1974,1(4):537-553.