A Review of Force Sensing Technology in Robot-assisted Laparoscopic Surgery

Expand
  • 1.College of Artificial Intelligence,Nankai University,Tianjin,300350
    2.Institute of Robotics & Automatic Information System,Nankai University,Tianjin,300350

Received date: 2020-11-20

  Online published: 2021-11-16

Abstract

In order to promote the further research and clinical applications of force sensing technology in robot-assisted laparoscopic surgery, the research progresses were reviewed. Sensor force sensing was divided into two categories:electrical signal-based sensing and optical signal-based sensing. Some key indicators were analyzed, such as sensor position distribution on surgical instruments, mechanical structure, measurement range, measurement accuracy and electromagnetic compatibility. Sensors advantages and disadvantages were discussed. Sensorless force sensing was divided into two categories:vision-based sensing and dynamic model-based sensing. And the realization method, technical obstacle and error sources were analyzed. Finally, the development trend of force sensing technology in robot-assisted laparoscopic surgery was prospected. 

Cite this article

ZHANG Jianxun, YAO Bin, DAI Yu, XIA Guangming, . A Review of Force Sensing Technology in Robot-assisted Laparoscopic Surgery[J]. China Mechanical Engineering, 2021 , 32(21) : 2521 -2531 . DOI: 10.3969/j.issn.1004-132X.2021.21.001

References

[1]BROUWER I, USTIN J, BENTLEY L M, et al. Measuring in Vivo Animal Soft Tissue Properties for Haptic Modeling in Surgical Simulation[J]. Stud. Health Technol. Inform., 2001, 81:69-74. 
[2]OKAMURA A M. Haptic Feedback in Robot-assisted Minimally Invasive Surgery[J]. Current Opinion in Urology, 2009, 19(1):102-107. 
[3]付宜利, 李坤, 潘博, 等. 微创手术机器人力检测与力反馈技术研究现状[J]. 机器人, 2014, 36(1):117-128. 
FU Yili, LI Kun, PAN Bo, et al. A Survey of Force Sensing and Force Feedback Technology for Robot-assisted Minimally Invasive Surgical System[J]. Robot, 2014, 36(1):117-128. 
[4]SAUERLAND S, JASCHINSKI T, NEUGEBAUER E. Laparoscopic versus Open Surgery for Suspected Appendicitis[J]. Cochrane Database of Systematic Reviews, 2018(11):CD001546. 
[5]OKAMURA A M. Methods for Haptic Feedback in Teleoperated Robot-assisted Surgery[J]. Industrial Robot, 2004, 31(6):499-508. 
[6]DINESH V, SEAN C. Peer Review and Surgical Innovation:Robotic Surgery and Its Hurdles[J]. American Journal of Robotic Surgery, 2015, 2(1):39-44. 
[7]GWILLIAM J C, MAHVASH M, VAGVOLGYI B, et al. Effects of Haptic and Graphical Force Feedback on Teleoperated Palpation[C]∥ International Conference on Robotics and Automation. Kobe, 2009:677-682. 
[8]WAGNER C R, STYLOPOULOS N, JACKSON P G, et al. The Benefit of Force Feedback in Surgery:Examination of Blunt Dissection[J]. Presence:Teleoperators Virtual Environments, 2007, 16(3):252-262. 
[9]REILEY C E, AKINBIYI T, BURSCHKA D, et al. Effects of Visual Force Feedback on Robot-assisted Surgical Task Performance[J]. The Journal of Thoracic Cardiovascular Surgery, 2008, 135(1):196-202.
[10]DEMI B, ORTMAIER T, SEIBOLD U. The Touch and Feel in Minimally Invasive Surgery[C]∥ IEEE International Workshop on Haptic Audio Visual Environments and Their Applications. Ottawa, 2005:8894919. 
[11]DARGAHI J, NAJARIAN S. An Endoscopic Force-position Sensor Grasper with Minimum Sensors[J]. Canadian Journal of Electrical Computer Engineering, 2003, 28(3):155-161. 
[12]PRASAD S K, KITAGAWA M, FISCHER G S, et al. A Modular 2-DOF Force-sensing Instrument for Laparoscopic Surgery[C]∥ Proceedings of the International Conference on Medical Image Computing and Computer Assisted Intervention. Montreal, 2003:279-286. 
[13]FISCHER G S, AKINBIYI T, SAHA S, et al. Ischemia and Force Sensing Surgical Instruments for Augmenting Available Surgeon Information[C]∥ The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. Pisa, 2006:1030-1035. 
[14]LI K, PAN B, ZHAN J, et al. Design and Performance Evaluation of a 3-axis Force Sensor for MIS Palpation[J]. Sensor Review, 2015, 35(2):219-228. 
[15]代煜, 张建勋. 基于小波变换和维纳滤波的半导体器件1/f噪声滤波 [J]. 物理学报, 2011, 60(11):185-190. 
DAI Yu, ZHANG Jianxun. Reduction of 1/f Noise in Semiconductor Devices Based on Wavelet Transform and Wiener Filter[J]. Acta Physica Sinica, 2011, 60(11):185-190. 
[16]孙会娇, 代煜, 张建勋, 等. 直流电源激励下的电路高分辨力应变信号处理 [J]. 仪器仪表学报, 2019, 40(8):184-190. 
SUN Huijiao, DAI Yu, ZHANG Jianxun, et al. High Resolution Strain Signal Processing for the Circuit under DC Source Excitation[J]. Chinese Journal of Scientific Instrument, 2019, 40(8):184-190. 
[17]SOKHANVAR S, PACKIRISAMY M, DARGAHI J. A Multifunctional PVDF-based Tactile Sensor for Minimally Invasive Surgery[J]. Smart Materials Structures, 2007, 16(4):989-998. 
[18]SOKHANVAR S, PACKIRISAMY M, DARGAHI J. MEMS Endoscopic Tactile Sensor:Toward In-situ and In-vivo Tissue Softness Characterization[J]. IEEE Sensors Journal, 2009, 9(12):1679-1687. 
[19]DAI Y, ABIRI A, LIU S, et al. Grasper Integrated Tri-axial Force Sensor System for Robotic Minimally Invasive Surgery[C]∥ 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society(EMBC). Jeju, 2017:3936-3939. 
[20]KIM U, KIM Y B, SO J, et al. Sensorized Surgical Forceps for Robotic-assisted Minimally Invasive Surgery[J]. IEEE Transactions on Industrial Electronics, 2018, 65(12):9604-9613. 
[21]DARGAHI J, PARAMESWARAN M. A Micromachined Piezoelectric Tactile Sensor for an Endoscopic Grasper-theory, Fabrication and Experiments[J]. Journal of Microelectromechanical Systems, 2000, 9(3):329-335. 
[22]SEIBOLD U, HIRZINGER G. A 6-axis Forche/Torque Sensor Design for Haptic Feedback in Minimally Invasive Robotic Surgery[C]∥ 2nd VDE World Microtechnologies Congress. Munich, 2003:239-244. 
[23]KALANTARI M, RAMEZANIFARD M, AHMADI R, et al. A Piezoresistive Tactile Sensor for Tissue Characterization during Catheter-based Cardiac Surgery[J]. International Journal of Medical Robotics and Computer Assisted Surgery, 2011, 7(4):431-440. 
[24]BAKI P, SZEKELY G, KOSA G. Miniature Tri-axial Force Sensor for Feedback in Minimally Invasive Surgery[C]∥ 4th IEEE RAS & EMBS International Conference on Biomedical Robotics & Biomechatronics. Rome, 2012:12967935. 
[25]HWANG J H, KWON J H, KIM T K, et al. Design of Simple Structured Tactile Sensor for the Minimally Invasive Robotic Palpation[C]∥ IEEE/ASME International Conference on Advanced Intelligent Mechatronics. Wollongong, 2013:1296-1299. 
[26]LEE J, CHOI W, YOO Y K, et al. A Micro-fabricated Force Sensor Using an All Thin Film Piezoelectric Active Sensor[J]. Sensors, 2014, 14(12):22199-22207. 
[27]KIM U, LEE D H, YOON W J, et al. Force Sensor Integrated Surgical Forceps for Minimally Invasive Robotic Surgery[J]. IEEE Transactions on Robotics, 2016, 31(5):1214-1224. 
[28]LEE D H, KIM U, GULREZ T, et al. A Laparoscopic Grasping Tool with Force Sensing Capability[J]. IEEE/ASME Transactions on Mechatronics, 2016, 21(1):130-141. 
[29]HESSINGER M, PILIC T, WERTHSCHUTZKY R, et al. Miniaturized Force/Torque Sensor for in Vivo Measurements of Tissue Characteristics[C]∥ International Conference of the IEEE Engineering in Medicine & Biology Society. Orlando, 2016:2022-2025. 
[30]KIM U, KIM Y B, SEOK D, et al. A Surgical Palpation Probe with 6-axis Force/Torque Sensing Capability for Minimally Invasive Surgery[J]. IEEE Transactions on Industrial Electronics, 2018, 65(3):2755-2765. 
[31]YU L, YAN Y, YU X, et al. Design and Realization of Forceps with 3-D Force Sensing Capability for Robot-assisted Surgical System[J]. IEEE Sensors Journal, 2018, 18(21):8924-8932. 
[32]PUANGMALI P, LIU H, SENEVIRATNE L, et al. Miniature 3-axis Distal Force Sensor for Minimally Invasive Surgical Palpation[J]. IEEE-ASME Transactions on Mechatronics, 2012, 17(4):646-656. 
[33]FONTANELLI G A, BUONOCORE L R, FICUCIELLO F, et al. A Novel Force Sensing Integrated into the Trocar for Minimally Invasive Robotic Surgery[C]∥ IEEE/RSJ International Conference on Intelligent Robots and Systems(IROS). Vancouver, 2017:131-136. 
[34]ZEMITI N, MOREL G, ORTMAIER T, et al. Mechatronic Design of a New Robot for Force Control in Minimally Invasive Surgery[J]. IEEE/ASME Transactions on Mechatronics, 2007, 12(2):143-153. 
[35]BANDARI N, DARGAHI J, PACKIRISAMY M. Miniaturized Optical Force Sensor for Minimally Invasive Surgery with Learning-based Nonlinear Calibration[J]. IEEE Sensors Journal, 2020, 20(7):3579-3592. 
[36]HASLINGER R, LEYENDECKER P, SEIBOLD U. A Fiberoptic Force-Torque-sensor for Minimally Invasive Robotic Surgery[C]∥ IEEE International Conference on Robotics and Automation. Karlsruhe, 2013:4390-4395. 
[37]HOSEOK S, HEECHUL K, JUWON J, et al. Development of FBG Sensor System for Force-feedback in Minimally Invasive Robotic Surgery[C]∥ 5th International Conference on Sensing Technology. Palmerston North, 2011:16-20. 
[38]LYU C, WANG S, SHI C. A High-precision and Miniature Fiber Bragg Grating-based Force Sensor for Tissue Palpation during Minimally Invasive Surgery[J]. Annals of Biomedical Engineering, 2019, 48(20):669-681. 
[39]姚斌, 张建勋, 代煜, 等. 用于微创外科手术机器人的多维力传感器解耦方法研究[J]. 仪器仪表学报, 2020, 41(1):147-153. 
YAO Bin, ZHANG Jianxun, DAI Yu, et al. Research on Decoupling Method of Multi-dimensional Force Sensor Used in Minimally Invasive Surgical Robot[J]. Chinese Journal of Scientific Instrument, 2020, 41(1):147-153. 
[40]TADA M, SASAKI S, OGASAWARA T. Development of an Optical 2-axis Force Sensor Usable in MRI Environments[C]∥ Proceedings of IEEE Sensors. Orlando, 2002:984-989. 
[41]PEIRS J, CLIJNEN J, REYNAERTS D, et al. A Micro Optical Force Sensor for Force Feedback during Minimally Invasive Robotic Surgery[J]. Sensors and Actuators A:Physical, 2004, 115(2):447-455. 
[42]MULLER M, HOFFMANN L, BUCK T, et al. Fiber Bragg Grating-based Force-Torque Sensor with Six Degrees of Freedom[J]. International Journal of Optomechatronics, 2009, 3(3):201-214. 
[43]POLYGERINOS P, SCHAEFFTER T, SENEVIRATNE L, et al. A Fibre-optic Catheter-tip Force Sensor with MRI Compatibility:a Feasibility Study[C]∥Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Minneapolis, 2009:1501-1504. 
[44]AHMADI R, ARBATANI S, PACKIRISAMY M, et al. Micro-optical Force Distribution Sensing Suitable for Lump/Artery Detection[J]. Biomedical Microdevices, 2015, 17:10. 
[45]XUE R F, REN B Y, HUANG J Q, et al. Design and Evaluation of FBG-based Tension Sensor in Laparoscope Surgical Robots[J]. Sensors, 2018, 18:2067. 
[46]ZARRIN P S, ESCOTO A, XU R, et al. Development of a 2-DOF Sensorized Surgical Grasper for Grasping and Axial Force Measurements[J]. IEEE Sensors Journal, 2018, 18(7):2816-2826. 
[47]LI T, SHI C, REN H. A High-sensitivity Tactile Sensor Array Based on Fiber Bragg Grating Sensing for Tissue Palpation in Minimally Invasive Surgery[J]. IEEE/ASME Transactions on Mechatronics, 2018, 23(5):2306-2315. 
[48]SHI C, LI M, LYU C, et al. A High-sensitivity Fiber Bragg Grating-based Distal Force Sensor for Laparoscopic Surgery[J]. IEEE Sensors Journal, 2020, 20(5):2467-2475. 
[49]NOOHI E, PARASTEGARI S, EFRAN M. Using Monocular Images to Estimate Interaction Forces during Minimally Invasive Surgery[C]∥ 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems. Chicago, 2014:4297-4302. 
[50]GESSERT N, BERINGHOFF J, OTTE C, et al. Force Estimation from OCT Volumes Using 3D CNNs[J]. International Journal of Computer Assisted Radiology and Surgery, 2018, 13(7):1073-1082. 
[51]ROSEN J, HANNAFORD B, MACFARLANE M P, et al. Force Controlled and Teleoperated Endoscopic Grasper for Minimally Invasive Surgery-experimental Performance Evaluation[J]. IEEE Transactions on Biomedical Engineering, 1999, 46(10):1212-1221. 
[52]SANG H, YUN J, MONFAREDI R, et al. External Force Estimation and Implementation in Robotically Assisted Minimally Invasive Surgery[J]. International Journal of Medical Robotics and Computer Assisted Surgery, 2017, 13(2):28466997. 
[53]THOLEY G, PILLARISETTI A, GREEN W, et al. Design, Development, and Testing of an Automated Laparoscopic Grasper with 3-D Force Measurement Capability[C]∥ International Symposium on Medical Simulation. Cambridge, 2004:38-48. 
[54]KENNEDY C W, DESAI J P. A Vision-based Approach for Estimating Contact Forces:Applications to Robot-assisted Surgery[J]. Applied Bionics and Biomechanics, 2005, 2(1):53-60. 
[55]YOON S M, LEE M, KIM C. Sliding Perturbation Observer Based Reaction Force Estimation Method of Surgical Robot Instrument for Haptic Realization[J]. International Journal of Humanoid Robotics, 2015, 12(2):1550013. 
[56]AVILES A I, ALSALEH S, SOBREVILLA P, et al. Sensorless Force Estimation Using a Neuro-vision-based Approach for Robotic-assisted Surgery[C]∥ 7th International IEEE/EMBS Conference on Neural Engineering(NER). Montpellier, 2015:86-89. 
[57]RAHMAN N, LEE M. Actual Reaction Force Separation Method of Surgical Tool by Fuzzy Logic Based SMCSPO[J]. International Journal of Control, Automation, and Systems, 2015, 13(2):379-389. 
[58]ZHAO B, NELSON C A. Estimating Tool-tissue Forces Using a 3-Degree-of-freedom Robotic Surgical Tool[J]. Journal of Mechanisms and Robotics, 2016, 8(5):051015. 
[59]LIN W, SONG K. Instrument Contact Force Estimation Using Endoscopic Image Sequence and 3D Reconstruction Model[C]∥ 2016 International Conference on Advanced Robotics and Intelligent Systems(ARIS). Taipei, 2016:16774744. 
[60]LI Y, HANNAFORD B. Gaussian Process Regression for Sensorless Grip Force Estimation of Cable-driven Elongated Surgical Instruments[J]. IEEE Robotics and Automation Letters, 2017, 2(3):1312-1319. 
[61]HWANG W, LIM S. Inferring Interaction Force from Visual Information without Using Physical Force Sensors[J]. Sensors, 2017, 17(11):2455. 
[62]WANG Z Y, WANG D M, CHEN B, et al. A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-driven Surgical Robot End-effectors[J]. Sensors(Basel), 2019, 19(23):5291. 
[63]XUE R F, DU Z J, YAN Z Y, et al. An Estimation Method of Grasping Force for Laparoscope Surgical Robot Based on the Model of a Cable-pulley System[J]. Mechanism and Machine Theory, 2019, 134:440-454. 
Outlines

/

〈 〉