A piezoelectric impedance shift method was proposed to detect bolt looseness based on changes of piezoeletric impedance frcquency. A piezoelectric patch was bonded on the head of the bolt, and a material testing machine was adopted to apply tension force precisely on the tested bolt to simulate pre-tightening forces of bolts. The shift of a specified peak frequency in piezoelectric admittance spectrum was measured by a precision impedance analyzer in clean environments and oil pollution environments. The experimental results show that the specified peak frequency decreases while bolt preload increases, and the frequency shift has a linear relationship with the preload on the bolt, and oil pollution has a little effects on the experimental results.
SHAO Junhua
,
WANG Tao
,
WANG Zhengao
,
WEI Denglai
,
LI Yourong
. Bolt Looseness Detection Using Piezoelectric Impedance Frequency Shift Method[J]. China Mechanical Engineering, 2019
, 30(12)
: 1395
-1399,1408
.
DOI: 10.3969/j.issn.1004-132X.2019.12.002
[1] KIM N, HONG M. Measurement of Axial Stress Using Mode-converted Ultrasound[J]. NDT & E International, 2009, 42(3):164-169.
[2] WANG Tao, SONG Gangbing, LIU Shaopeng, et al. Review of Bolted Connection Monitoring[J]. International Journal of Distributed Sensor Networks, 2013, 9(12):871213.
[3] AMERINI F, MEO M. Structural Health Monitoring of Bolted Joints Using Linear and Nonlinear Acoustic/Ultrasound Methods[J]. Structural Health Monitoring, 2011, 10(6):659-672.
[4] PAN Q, LIU S, LI X, et al. Characteristic Evaluation on Bolt Stress by Ultrasonic Nondestructive Methods[J]. Advances in Materials Science and Engineering, 2015(2):1-6.
[5] PAN Q, MI Y, WEI Y, et al. A Method of Testing Residual Stress by Ultrasonic Shear and Longitudinal Waves[C]//2016 IEEE International Conference on Mechatronics and Automation (ICMA). Harbin, 2016:1295-1299.
[6] LIANG C, SUN F P, ROGERS C A. Coupled Electro-mechanical Analysis of Adaptive Material Systems-determination of the Actuator Power Consumption and System Energy Transfer[J]. Journal of Intelligent Material Systems and Structures, 1997, 8(4):335-343.
[7] GIURGIUTIU V, ZAGRAI A N. Characterization of Piezoelectric Wafer Active Sensors[J]. Journal of Intelligent Material Systems and Structures, 2000, 11(12):959-976.
[8] ANNAMDAS V G M, SOH C K. Application of Electromechanical Impedance Technique for Engineering Structures:Review and Future Issues[J]. Journal of Intelligent Material Systems and Structures, 2010, 21(1):41-59.
[9] LIM Y Y, SOH C K. Effect of Varying Axial Load under Fixed Boundary Condition on Admittance Signatures of Electromechanical Impedance Technique[J]. Journal of Intelligent Material Systems and Structures, 2012, 23(7):815-826.
[10] HAQ M U, BHALLA S, NAQVI T. Fatigue Damage Assessment of RC Column Using PZT Sensors[J]. Procedia Engineering, 2017, 173:1223-1230.
[11] 高峰, 王德俊, 江钟伟, 等. 压电阻抗技术用于螺栓松紧健康诊断[J]. 中国机械工程, 2001, 12(9):1048-1050. GAO Feng, WANG Dejun, JIANG Zhongwei, et al. Research on Piezoelectric Impedance Technology for Bolt Health Monitoring[J]. China Mechanical Engineering, 2001, 12(9):1048-1050.
[12] 王涛, 杨志武, 邵俊华, 等. 基于压电阻抗技术的螺栓松动检测试验研究[J]. 传感技术学报, 2014, 27(10):1311-1325.WANG Tao, YANG Zhiwu, SHAO Junhua, et al. Research on Bolt Loosen Detection Based on Piezoelectric Impedance Technology[J]. Chinese Journal of Sensors and Actuator, 2014, 27(10):1311-1325.
[13] 汪正傲,王涛,李友荣, 等.基于螺母外侧压电材料阻抗峰值频率变化的螺栓松动监测[J].传感技术学报, 2018, 31(6):861-865.WANG Zhengao, WANG Tao, LI Yourong, et al. Bolt Looseness Monitoring Based on the Peak Frequency Shift of Piezoelectric Material on the Nut[J]. Chinese Journal of Sensors and Actuators, 2018, 31(6):861-865.