Design and Mechanics Analysis of Biodegradable Polymer Vascular Stents with High Radial Supporting Property

  • WEI Yunbo ,
  • ZHAO Danyang ,
  • WANG Minjie ,
  • LI Hongxia
Expand
  • School of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning, 116024

Received date: 2019-04-03

  Online published: 2020-06-15

Abstract

Based on the study of the relationship between strut angle of a stent and the radial supporting strength, a novel design method was proposed herein. Specifically, unequal-height supporting rings were used to increase the strut angle after expansion and furthermore improve the radial strength. Using this method, three kinds of biodegradable polymer vascular stents were designed. Radial strength, radial recoil, axial foreshortening and bending stiffness of the three stents were analyzed by finite element method and compared with Abbott bioresorbable vascular scaffolds(BVS). The influences of the structures on properties of the stents were studied. The radial strength of the designed JS(J-type stent), OCS(open C-type stent) and CCS(closed C-type stent) is as 14%, 34% and 42% higher than that of the BVS, respectively. The recoil of the designed stents is about 21% lower than that of the BVS. Meanwhile, all the designed stents have no axial shortening. The bending stiffness of the JS and OCS, which have open cells, is comparable to that of BVS and is about 73% lower than that of the CCS, which has closed cells. The radial supporting strength and radial recoil mainly depend on the structural form of the supporting rings. These two properties may be effectively improved by employing unequal-height supporting rings. The axial foreshortening is mainly determined by the structural form and the connection positions of the bridges. The axial shortening of the stents may be avoided by using bridges with curved structures and setting the connection positions in the middle of the straight section of the supporting elements. The bending stiffness is mainly affected by the connection form between the bridges and the supporting rings. The bending stiffness is lower if the stent has open cells.

Cite this article

WEI Yunbo , ZHAO Danyang , WANG Minjie , LI Hongxia . Design and Mechanics Analysis of Biodegradable Polymer Vascular Stents with High Radial Supporting Property[J]. China Mechanical Engineering, 2020 , 31(9) : 1098 -1107 . DOI: 10.3969/j.issn.1004-132X.2020.09.012

References

[1] BRIE D, PENSON P, SERBAN M C, et al. Bioresorbable Scaffold-a Magic Bullet for the Treatment of Coronary Artery Disease[J]. International Journal of Cardiology, 2016, 215:47-59.
[2] BOLAND E L, SHINE R, KELLY N, et al. A Review of Material Degradation Modelling for the Analysis and Design of Bioabsorbable Stents[J]. Annals of Biomedical Engineering, 2015, 44(2):341-356.
[3] GOGAS B D. Bioresorbable Scaffolds for Percutaneous Coronary Interventions[J]. Global Cardiology Science and Practice, 2014, 2014(4):409-427.
[4] WIEBE J, NEF H M, HAMM C W. Current Status of Bioresorbable Scaffolds in the Treatment of Coronaryartery Disease[J]. Journal of the American College of Cardiology, 2014, 64(23):2541-2551.
[5] 郑利萍,贾莉芳,袁暾,等.新型可降解聚合物血管支架的体内血栓形成评价[J].生物医学工程学杂志, 2019, 36(2):1-6. ZHENG Liping, JIA Lifang, YUAN Tun, et al. The in vivo Thrombosis Evaluation for the Biodegradable Polymer Stent[J]. Journal of Biomedical Engineering, 2019, 36(2):1-6.
[6] CAIAZZO G, KILIC I D, FABRIS E, et al. Absorb Bioresorbable Vascular Scaffold:What Have We Learned after 5 Years of Clinical Experience?[J]. International Journal of Cardiology, 2015, 201:129-136.
[7] SOARES J S, MOORE J E. Biomechanical Challenges to Polymeric Biodegradable Stents[J]. Annals of Biomedical Engineering, 2016, 44(2):1-20.
[8] FOIN N, LEE R D, TORII R, et al. Impact of Stent Strut Design in Metallic Stents and Biodegradable Scaffolds[J]. International Journal of Cardiology, 2014, 177(3):800-808.
[9] HUI Y A, BULLUCK H, WONG P, et al. Bioresorbable Stents:Current and Upcoming Bioresorbable Technologies[J]. International Journal of Cardiology, 2017, 228:931-939.
[10] TENEKECIOGLU E, FAROOQ V, BOURANTAS C V, et al. Bioresorbable Scaffolds:a New Paradigm in Percutaneous Coronary Intervention[J]. BMC Cardiovascular Disorders, 2016, 16(1):38.
[11] HOU Lida, LI Zhen, PAN Yu, et al. A Review on Biodegradable Materials for Cardiovascular Stent Application[J]. Frontiers of Materials Science, 2016, 10(3):238-259.
[12] LINDHOLM D, JAMES S. Bioresorbable Stents in PCI[J]. Current Cardiology Reports, 2016, 18(8):1-6.
[13] KOCKA V, TOUSEK P, WIDIMSKY P. Absorb Bioresorbable Stents for the Treatment of Coronary Artery Disease[J]. Expert Review of Medical Devices, 2015, 12(5):545-557.
[14] ALEXY R D, LEVI D S. Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent[J]. BioMed Research International, 2013, 18:137985.
[15] ANG H Y, HUANG Y Y, LIM S T, et al. Mechanical Behavior of Polymer-based vs. Metallic-based Bioresorbable Stents[J]. Journal of Thoracic Disease, 2017, S9:S923.
[16] 赵丹阳,刘韬,李红霞,等.可降解聚合物血管支架结构优化设计[J].力学学报, 2017, 49(6):1409-1417. ZHAO Danyang, LIU Tao, LI Hongxia, et al.Optimization Design of Degradable Polymer Vascular Stent Structure[J]. Chinese Journal of Theoretical and Applied Mechanics, 2017, 49(6):1409-1417.
[17] 李萍萍,张若京.具有周期结构的血管支架有限元分析[J].工程力学, 2012, 29(9):369-374. LI Pingping, ZHANG Ruojing. Finite Element Analysis of Stent with Periodic Structure[J]. Engineering Mechanics, 2012, 29(9):369-374.
[18] WU W, PETRINI L, GASTALDI D, et al. Finite Element Shape Optimization for Biodegradable Magnesium Alloy Stents[J]. Annals of Biomedical Engineering, 2010, 38(9):2829-2840.
[19] HSIAO H M, CHIU Y H, LEE K H, et al. Computational Modeling of Effects of Intravascular Stent Design on Key Mechanical and Hemodynamic Behavior[J]. Computer-Aided Design, 2012, 44(8):757-765.
[20] AZAOUZI M, MAKRADI A, BELOUETTAR S. Numerical Investigations of the Structural Behavior of a Balloon Expandable Stent Design Using Finite Element Method[J]. Computational Materials Science, 2013, 72(9):54-61.
[21] MORI K, SAITO T. Effects of Stent Structure on Stent Flexibility Measurements[J]. Annals of Biomedical Engineering, 2005, 33(6):733.
[22] FENG Q, JIANG W, SUN K, et al. Mechanical Properties and in Vivo Performance of a Novel Sliding-lock Bioabsorbable Poly-dioxanone Stent[J]. Journal of Materials Science Materials in Medicine, 2011, 22(10):2319-2327.
[23] BOURANTAS C V, ZHANG Y J, FAROOQ V, et al. Bioresorbable Scaffolds:Current Evidence and Ongoing Clinical Trials[J]. Current Cardiology Reports, 2012, 14(5):626-634.
[24] YANG J, HUANG N. Mechanical Formula for the Plastic Limit Pressure of Stent during Expansion[J]. Acta Mechanica Sinica, 2009, 25(6):795-801.
[25] LI H, LIU T, WANG M, et al. Design Optimization of Stent and Its Dilatation Balloon Using Kriging Surrogate Model[J]. Biomedical Engineering Online, 2017, 16(1):13.
[26] TAKASHIMA K, KITOU T, MORI K, et al. Simulation and Experimental Observation of Contact Conditions between Stents and Artery Models[J]. Medical Engineering & Physics, 2007, 29(3):326-335.
[27] LI Junlei, ZHENG Feng, QIU Xun, et al. Finite Element Analyses for Optimization Design of Biodegradable Magnesium Alloy Stent[J]. Materials Science & Engineering C, 2014, 42:705-714.
[28] ASTM International. F2079-09(2017) Standard Test Method for Measuring Intrinsic Elastic Recoil of Balloon-Expandable Stents[S]. West Conshohocken, PA:ASTM International Press, 2017:1-3.
[29] ASTM International. F2081-06(2017) Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents[S]. West Conshohocken, PA:ASTM International Press, 2017:1-3.
[30] ASTM International. F3067-14 Guide for Radial Loading of Balloon Expandable and Self Expanding Vascular Stents[S]. West Conshohocken, PA:ASTM International Press, 2014:1-3.
[31] 李红霞.冠脉支架的力学行为研究及其优化设计[D].大连:大连理工大学,2014. LI Hongxia. Mechanical Behavior Research and Design Optimization of Coronary Stent[D]. Dalian:Dalian University of Technology, 2014.
Outlines

/

〈 〉