Traditional atomization devices always exhibit many drawbacks, such as non-uniform atomization particle sizes, instability of transient atomization quantity and uncontrollability of precise energy, which seriously restrict further practical application of atomization inhalation therapy. The formation and separation process of droplets belongs to a microphenomenon of atomization. The investigation of the droplet formation and separation process will be favorable for understanding the atomization mechanism. In present work, the Conservative Level Set Method (CLSM) is successfully applied on the simulation of the formation and separation of droplets in a medical piezoelectric atomization device induced by intra-hole fluctuation. The intra-hole fluctuation mechanism is systematically explored and analyzed, and also the expression of the volume change in the micro cone hole is built and evaluated. Both the control equation and simulation model of droplet formation and separation process have been well established by meshing the simulation model, and thereby the process of droplet formation and separation is simulated. The corresponding results demonstrate that the breaking time of droplets is decreased with the inlet velocity and liquid temperature rising, while enhanced with the liquid concentration increasing. Meanwhile, the volume of droplet is decreased with the inlet velocity and liquid concentration increasing, but increased with the liquid temperature rising. The velocity of droplet is enhanced with the inlet velocity and liquid temperature rising, and reduced with the increase of liquid concentration. When the large side diameter of micro-cone hole is set as 79 μm, the breaking time of the droplet reaches a minimum value of 38.7 μs, whereas the volume and the velocity of droplet reach a maximum value of 79.8 pL and 4.46 m/s, respectively. This study provides theoretical guidance for the design of medical piezoelectric atomization devices and contributes to the promotion of inhalation therapy in practical use.
[1] B Shah, P Modi, R S Sagar. In silico studies on therapeutic agents for COVID-19: Drug repurposing approach. Life Sciences, 2020, 252: 117652.
[2] M Nioi, P E Napoli. The waiver of patent protections for COVID-19 vaccines during the ongoing pandemic and the conspiracy theories: lights and shadows of an issue on the ground. Frontiers in Medicine, 2021, 8: 756623.
[3] S Surina, K Martinsone, V Perepjolkina, et al. Factors related to COVID-19 preventive behaviors: a structural equation model. Frontiers in Psychology, 2021, 12: 676521.
[4] K Dorgham, A U Neumann, M Decavele, et al. Considering personalized interferon beta therapy for COVID-19. Antimicrobial Agents and Chemotherapy, 2021, 65(4): e00065-21.
[5] A E Frankel, R Reddy, K R DeSuza, et al. Response to pegylated interferon in a COVID-19-positive elderly woman with primary myelofibrosis treated with ruxolitinib. Clinical Cased Reports, 2021, 9(4): 2228-2235.
[6] L Vecellio. The mesh nebuliser: a recent technical innovation for aerosol delivery. Breathe, 2006, 2(3): 252-260.
[7] C Y Lin, H C Meng, C Fu. An ultrasonic aerosol therapy nebulizer using electroformed palladium-nickel alloy nozzle plates. Sensors and Actuators A: Physical, 2011, 169: 187-193.
[8] M Beck-Broichsitter, P Kleimann, T Gessler. Nebulization performance of biodegradable sildenafil-loaded nanoparticles using the Aeroneb® Pro: Formulation aspects and nanoparticle stability to nebulization. International Journal of Pharmaceutics, 2012, 422(1): 398-408.
[9] S D McCarthy, H E González, B D Higgins. Future trends in nebulized therapies for pulmonary disease. Journal of Personalized Medicine, 2020, 10(2): 37.
[10] E Pourheidar, M Haghighi, M Kouchek, et al. Comparison of intravenous ampicillin-sulbactam plus nebulized colistin with intravenous colistin plus nebulized colistin in treatment of ventilator associated pneumonia caused by multi drug resistant acinetobacter baumannii: Randomized open label trial. Iranian Journal of Pharmaceutical Research, 2019, 18 (1): 269-281.
[11] A Q Nguyen, A Y Denault, Y Théoret, et al. Inhaled milrinone in cardiac surgical patients: A pilot randomized controlled trial of jet vs. mesh nebulization. Scientific Reports, 2020, 10: 2069.
[12] L Olseni, J Palmer, P Wollmer. Quantitative evaluation of aerosol deposition pattern in the lung in patients with chronic bronchitis. Physiological Measurement, 1994, 1(5): 41-48.
[13] J P Mitchell, M W Nagel. Particle size analysis of aerosols from medicinalinhalers, Powder & Particle, 2004: 32-65.
[14] F H Harlow, J E Welch. Numerical calculation of time-dependent viscous incompressible flow. Physics of Fluids, 1965, 8: 2182-2189.
[15] A A Amsden, F H Harlow. A simplified MAC technique for incompressible fluid calculation. Journal of Computational Physics, 1970, 6: 322-325.
[16] M Akhlaghi, V Mohammadi, N M Nouri, et al. Multi-fluid VOF model assessment to simulate the horizontal air-water intermittent flow. Chemical Engineering Research & Design, 2019, 152: 48-59.
[17] Y Yin, W D Zhu, J X Li, et al. Structural topology optimization using a level set method with finite difference updating scheme. Structural and Multidisciplinary Optimization, 2021, 63(4): 1839-1852.
[18] H M Zong, H Liu, Q P Ma, et al. VCUT level set method for topology optimization of functionally graded cellular structures. Computer Methods in Applied Mechanics and Engineering, 2019, 354(1): 487-505.
[19] Y Jiang, H Li, C Chen, et al. Calculation and verification of formula for the range of sprinklers based on jet breakup length. International Journal of Agricultural & Biological Engineering, 2018, 11(1): 49-57.
[20] E Olsson, G Kreiss, S Zahedi. A conservative level set method for two phase flow II. Journal of Computational Physics, 2007, 225: 785-807.
[21] C Bahbah, M Khalloufi, A Larcher, et al. Conservative and adaptive level-set method for the simulation of two-fluid flows. Computers & Fluids, 2019, 191: 104223.
[22] O Antepara, N Balcazar, A Oliva. Tetrahedral adaptive mesh refinements for two-phase flows using conservative level-set method. International Journal for Numerical Methods in Fluids, 2021, 93(2): 481-503.
[23] M Q de Luna, D Kuzmin, C E Kees. A monolithic conservative level set method with built-in redistancing. Journal of Computational Physics, 2019, 379: 262-278.
[24] A A Howard, A M Tartakovsky. A conservative level set method for N-phase flows with a free-energy-based surface tension model. Journal of Computational Physics, 2021, 426: 109955.
[25] Y F Cai, J H Zhang, C L Zhu, et al. Theoretical calculations and experimental verification for the pumping effect caused by the dynamic micro-tapered angle. Chinese Journal of Mechanical Engineering, 2016, 29(3): 615-623.
[26] Q F Yan, W T Sun, J H Zhang. Study on the influencing factors of the atomization rate in a piezoceramic vibrating mesh atomizer. Applied Sciences, 2020, 10: 2422.
[27] Q F Yan, W T Sun, L Zhang, et al. Effects of vibration characteristics on the atomization performance in the medical piezoelectric atomization device induced by intra-hole fluctuation. Chinese Journal of Mechanical Engineering, 2021, 34: 123.
[28] Q F Yan, C Y Wu, J H Zhang. Effect of the dynamic cone angle on the atomization performance of a piezoceramic vibrating mesh atomizer. Applied Sciences, 2019, 9: 1836.
[29] Q F Yan, J H Zhang, J Huang, et al. The effect of vibration characteristics on the atomization rate in a micro-tapered aperture atomizer. Sensors, 2018, 18(4): 934.
[30] J H Zhang, Q F Yan, J Huang, et al. Experimental verification of the pumping effect caused by the micro-tapered hole in a piezoelectric atomizer. Sensors, 2018, 18(7): 2311.