With the increasingly more extensive application of the medical surgical robot in the clinic, higher requirements have been put forward for medical robots. The bone-attached robot, a popular orthopedic robot in recent years, has a tendency of miniaturization and refinement. Thus, a bone-attached parallel manipulator (PM) based on 6-UCU (universal-cylindrical-universal) configuration is proposed, which is characterized by small volume, compact structure, high precision and six-dimensional force feedback. To optimize the structure and make it more compact, the workspace of the 6-UCU PM is analyzed based on the analysis of three kinds of constraint, and workspace model is established through spherical coordinate search method. This study also analyzes the influence of structural parameters on workspace, which may contribute to improving the efficiency of design and ensuring small-sized robots possess relatively large workspace. Moreover, to improve the motion accuracy, an error modeling method is developed based on the structure of 6-UCU PMs. According to this established error model, the output pose error curves are drawn using MATLAB software when the structure parameters change, and the influence of the structure and pose parameters change on the output pose error of PMs is analyzed. The proposed research provides the instruction to design and analysis of small PMs such as bone-attached robots.
Kaijie Dong
,
Duanling Li
,
Xingyu Xue
,
Chang Xu
,
Haowei Wang
,
Xianming Gao
. Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator[J]. Chinese Journal of Mechanical Engineering, 2022
, 35(3)
: 35
-35
.
DOI: 10.1186/s10033-022-00689-1
With the increasingly more extensive application of the medical surgical robot in the clinic, higher requirements have been put forward for medical robots. The bone-attached robot, a popular orthopedic robot in recent years, has a tendency of miniaturization and refinement. Thus, a bone-attached parallel manipulator (PM) based on 6-UCU (universal-cylindrical-universal) configuration is proposed, which is characterized by small volume, compact structure, high precision and six-dimensional force feedback. To optimize the structure and make it more compact, the workspace of the 6-UCU PM is analyzed based on the analysis of three kinds of constraint, and workspace model is established through spherical coordinate search method. This study also analyzes the influence of structural parameters on workspace, which may contribute to improving the efficiency of design and ensuring small-sized robots possess relatively large workspace. Moreover, to improve the motion accuracy, an error modeling method is developed based on the structure of 6-UCU PMs. According to this established error model, the output pose error curves are drawn using MATLAB software when the structure parameters change, and the influence of the structure and pose parameters change on the output pose error of PMs is analyzed. The proposed research provides the instruction to design and analysis of small PMs such as bone-attached robots.
[1] Z Huang, L F Kong. Mechanism theory and control of parallel manipulator. Beijing: China Machine Press, 1997. (in Chinese)
[2] J A Koenig, C Plaskos. Total knee arthroplasty technique: OMNIBotics. Berlin: Springer, 2019: 167-183.
[3] Y Liu, L Q Sun, Y B Fan. Overview and development of orthopedic robot. China Medical Devices, 2021, 36(1): 159-163. (in Chinese)
[4] T Ginoya, Y Maddahi, K Zareinia. A historical review of medical robotic platforms. Journal of Robotics, 2021. https://doi.org/10.1155/2021/6640031.
[5] L T Yan, Q Wang, H Y Wang, et al. Review of continue surgical robot actuated by SMA. Journal of Mechanical Engineering, 2021, 57(11): 138-152. (in Chinese)
[6] S Bahadori, T W Wainwright, P Subramanian, et al. A review of the evolution of robotic-assisted total hip arthroplasty. Hip International: the Journal of Clinical and Experimental Research on Hip Pathology and Therapy, 2019, 29(3): 232-238.
[7] J Douissard, M E Hagen, P Morel. The Da Vinci Surgical System. Bariatric Robotic Surgery, Cham: Springer, 2019: 13-27.
[8] X Wu, J Q Wang, X Sun, et al. Guidance for the treatment of femoral neck fracture with precise minimally invasive internal fixation based on the orthopaedic surgery robot positioning system. Orthopaedic Surgery, 2019, 11(3): 335-340.
[9] J Q Wang, Y B Fan. Results of treatment for femoral neck fracture will be improved by computer assisted orthopaedic surgery. China Journal of Orthopaedics and Traumatology, 2018, 31(2): 99-102. (in Chinese)
[10] P Kazanzides, B D Mittlelstadt, B L Musits, et al. An integrated system for cementless hip replacement. IEEE Engineering in Medicine and Biology, 1995: 307–313.
[11] J P Merlet. Parallel robots. 2nd ed. Dordrecht: Springer, 2006.
[12] B L Davies, K L Fan, R D Hibberd, et al. ACROBOT-using Robots and surgeons synergistically in knee surgery. Proceedings of the 8th IEEE International Conference on Advanced Robotics, 1997: 173-178.
[13] M Jakopec, S J Harris, Baena F, et al. The Acrobot system for total knee replacement. Industrial Robot, 2003, 30(1): 61-66.
[14] A Wolf, M Shohan, S Michael, et al. Morphometric study of the human lumbar spine for operation-workspace specifications. Spine, 2001, 26(22): 2472-2477.
[15] A Wolf, M Shohan, S Michael, et al. Feasibility study of a mini, bone-attached, robotic system for spinal operation. Spine, 2004, 29(2): 220-228.
[16] L Pransky. The Pransky interview: Professor Moshe Shoham, Founder of Mazor Robotics and Microbot Medical. Industrial Robot: An International Journal, 2014, 41(5): 393–397.
[17] B Fiani, S A Quadri, M Farooqui, et al. Impact of robot-assisted spine surgery on health care quality and neurosurgical economics: A systemic review. Neurosurgical Review, 2020, 43: 17–25.
[18] B Jiang, T D Azad, E Cottrill, et al. New spinal robotic technologies. Frontiers of Medicine, 2019, 13: 723–729.
[19] J Zhang, Y Q Zhao, J S Dai. Compliance modeling and analysis of a 3-RPS parallel kinematic machine module. Chinese Journal of Mechanical Engineering, 2014, 27(4): 703-713.
[20] K A Arrouk, B C Bouzgarrou, G Gogu. CAD based geometric procedures for workspace and singularity determination of the 3-RPR parallel manipulator. Applied Mechanics and Materials, 2012, 162: 131-140.
[21] H Xiong, X M Diao. Geometric isotropy indices for workspace analysis of parallel manipulators. Mechanism and Machine Theory, 2018(128): 648-662.
[22] J Fu, F Gao. Optimal Design of a 3-Leg 6-DOF parallel manipulator for a specific workspace. Chinese Journal of Mechanical Engineering, 2016, 30(4): 659-668.
[23] A Antonov, V Glazunov. Position, velocity, and workspace analysis of a novel 6-DOF parallel manipulator with "piercing" rods. Mechanism and Machine Theory, 2021, 161: 104300.
[24] Y D Xu, D S Zhang, M Wang, et al. Type synthesis of Two-Degrees-of-Freedom rotational parallel mechanism with two continuous rotational axes. Chinese Journal of Mechanical Engineering, 2016, 29(4): 694-702.
[25] T Sun, S F Yang, B B Lian. Finite and Instantaneous screw theory in robotic mechanism. Singapore: Springer, 2020.
[26] C Xu. Structure design and application of small 6-DOF parallel robot. Beijing: Beijing University of Post and Telecommunications, 2019. (in Chinese)
[27] Z H Zhan, X M Zhang, Z C Jian, et al. Error modelling and motion reliability analysis of a planar parallel manipulator with multiple uncertainties. Mechanism and Machine Theory, 2018, 124: 55-72.
[28] X H Zhao, Q Q Luan, L Zhao, et al. Kinematics modeling and error analysis of 3-RRRU parallel manipulator. Machinery Design & Manufacture, 2020, 01: 274-276, 280. (in Chinese)
[29] N Wang, T Zhang, Q H Wang. Kinematics error modeling and verification of 3UPS-PU parallel mechanism. Journal of Mechanical Transmission, 2020, 44(07): 113-118. (in Chinese)
[30] T Sun, Y M Song, Y G Li, et al. Separation of comprehensive geometrical errors of a 3-DOF PM based on Jacobian matrix and its sensitivity analysis with Monte-Carlo method. Chinese Journal of Mechanical Engineering, 2011, 24(3): 406-413.