In the nondestructive testing and evaluation area, magnetic major hysteresis loop measurement technology are widely applied for ferromagnetic material evaluation. However the characterization ability of major hysteresis loop measurement technology greatly varies as the evaluated target properties. To solve this limitation, magnetic minor hysteresis loops, which reflect the responses of ferromagnetic material magnetization in a systematic way, is recommend. Inspired by plenty of information carried by the minor loops, the sensitivity mapping technique was developed to achieve the highest sensitivity of minor-loop parameters to the nondestructively evaluated targets. In this study, for the first time, the sensitivity mapping technique is used to measure the tensile force in a steel strand and evaluate the effective case depth in induction-hardened steel rods. The method and procedures for the sensitivity mapping technique are given before experimental detection. The obtained experimental results indicate that the linear correlation between the induced voltage (or the magnetic induction intensity) and the tensile force (or effective case depth) exists at most of the locations in the cluster of minor loops. The obtained sensitivity maps can be used to optimize the applied magnetic field (or excitation current) and the analyzed locations at the minor loops for achieving the highest sensitivity. For the purpose of tensile force measurement, it is suggested that the strand should be firstly magnetized to the near-saturation state and then restored to the remanent state. In this way, the highest sensitivity is obtained as about 15.26 mV/kN. As for the induction-hardened steel rods, the highest sensitivity of magnetic induction intensity to the effective case depth occurs under low magnetic field conditions and the absolute value of the highest sensitivity is about 0.1110 T/mm. This indicates that if the highest sensitivity is required in the case depth evaluation, the induction-hardened steel rods are only required to be weakly magnetized. The proposed sensitivity mapping technique shows the good performance in the high-sensitivity evaluation of tensile force and case depth in ferromagnetic materials and its application scope can be extended to other nondestructive detection fields.
Cunfu He
,
Wenqiao Dou
,
Xiucheng Liu
,
Meng Yang
,
Ruifang Zhang
. A Sensitivity Mapping Technique for Tensile Force and Case Depth Characterization Based on Magnetic Minor Hysteresis Loops[J]. Chinese Journal of Mechanical Engineering, 2020
, 33(6)
: 84
-84
.
DOI: 10.1186/s10033-020-00508-5
In the nondestructive testing and evaluation area, magnetic major hysteresis loop measurement technology are widely applied for ferromagnetic material evaluation. However the characterization ability of major hysteresis loop measurement technology greatly varies as the evaluated target properties. To solve this limitation, magnetic minor hysteresis loops, which reflect the responses of ferromagnetic material magnetization in a systematic way, is recommend. Inspired by plenty of information carried by the minor loops, the sensitivity mapping technique was developed to achieve the highest sensitivity of minor-loop parameters to the nondestructively evaluated targets. In this study, for the first time, the sensitivity mapping technique is used to measure the tensile force in a steel strand and evaluate the effective case depth in induction-hardened steel rods. The method and procedures for the sensitivity mapping technique are given before experimental detection. The obtained experimental results indicate that the linear correlation between the induced voltage (or the magnetic induction intensity) and the tensile force (or effective case depth) exists at most of the locations in the cluster of minor loops. The obtained sensitivity maps can be used to optimize the applied magnetic field (or excitation current) and the analyzed locations at the minor loops for achieving the highest sensitivity. For the purpose of tensile force measurement, it is suggested that the strand should be firstly magnetized to the near-saturation state and then restored to the remanent state. In this way, the highest sensitivity is obtained as about 15.26 mV/kN. As for the induction-hardened steel rods, the highest sensitivity of magnetic induction intensity to the effective case depth occurs under low magnetic field conditions and the absolute value of the highest sensitivity is about 0.1110 T/mm. This indicates that if the highest sensitivity is required in the case depth evaluation, the induction-hardened steel rods are only required to be weakly magnetized. The proposed sensitivity mapping technique shows the good performance in the high-sensitivity evaluation of tensile force and case depth in ferromagnetic materials and its application scope can be extended to other nondestructive detection fields.
[1] Z Ma, Y Ma, F Zheng, et al. Modeling of hysteresis loop and its applications in ferroelectric materials. Ceramics International, 2018, 44(4): 4338-4343.
[2] C Li, G Shu, B Xu, et al. Effects of neutron irradiation on magnetic properties of reactor pressure vessel steel. Nuclear Engineering & Design, 2019, 342: 128-132.
[3] H L Ding, R Gao, T Zhang, et al. Annealing effect on the microstructure and magnetic properties of 14% Cr-ODS ferritic steel. Fusion Engineering and Design, 2015, 100: 371-377.
[4] S Kobayashi, F Gillemot, Á Horváth, et al. Investigation of effects of long-term thermal aging on magnetization process in low-alloy pressure vessel steels using first-order-reversal-curves. AIP Advances, 2017, 7(5): 056002.
[5] G Vertesy, I Tomáš, S Kobayashi. Nondestructive evaluation of low carbon steel by magnetic adaptive testing. Nondestructive Testing and Evaluation, 2010, 25(2): 125-132.
[6] U Aydin, P Rasilo, F Martin, et al. Modelling the effect of multiaxial stress on magnetic hysteresis of electrical steel sheets: A comparison. IEEE Conference on Electromagnetic Field Computation (CEFC), Miami, USA, November13-16, 2016.
[7] O Perevertov, R Schäfer. Influence of applied tensile stress on the hysteresis curve and magnetic domain structure of grain-oriented Fe-3% Si steel. Journal of Physics D: Applied Physics, 2014, 47(18): 185001.
[8] S Takahashi, S Kobayashi, I Tomáš, et al. Comparison of magnetic nondestructive methods applied for inspection of steel degradation. NDT & E International, 2017, 91: 54-60.
[9] S Takahashi, S Kobayashi, H Kikuchi, et al. Analysis of minor hysteresis loops of cold rolled low carbon steel. IEEE Transactions on Magnetics, 2006, 42(11): 3782-3784.
[10] S Kobayashi, S Takahashi, Y Kamada, et al. A low-field scaling rule of minor hysteresis loops in plastically deformed steels. IEEE Transactions on Magnetics, 2010, 46(2): 191-194.
[11] S Kobayashi, T Murakami, Y Narita, et al. Effects of cold rolling on magnetic minor hysteresis loops of duplex stainless steels. Philosophical Magazine, 2017, 97(6): 419-430.
[12] I Tomáš, G Vértesy. Adaptive testing for nondestructive evaluation of degraded materials. Journal of Electrical Engineering, 2016, 67(4): 273-278.
[13] I Tomáš, G Vértesy, F Gillemot, et al. Nondestructive Magnetic Adaptive Testing of nuclear reactor pressure vessel steel degradation. Journal of Nuclear Materials, 2013, 432(1): 371-377.
[14] G Vértesy, I Tomáš. Complex characterization of degradation of ferromagnetic materials by magnetic adaptive testing. IEEE Transactions on Magnetics, 2013, 49(6): 2881-2885.
[15] Tino Gottschall, E Stern-Taulats, L Mañosa, et al. Reversibility of minor hysteresis loops in magnetocaloric Heusler alloys. Applied Physics Letters, 2017, 110(22): 223904.
[16] M H Yoon, Y Y Choi, J P Hon. Improvement in thrust force estimation of solenoid valve considering minor hysteresis loop. AIP Advances, 2016, 7(5): 056607.
[17] M A Zambrello, A D Schuyler, M W Maciejewski, et al. Nonuniform sampling in multidimensional NMR for improving spectral sensitivity. Methods, 2018, 138-139: 62-68.
[18] X C Liu, B Wu, F Qin, et al. Observation of ultrasonic guided wave propagation behaviours in pre-stressed multi-wire structures. Ultrasonics, 2017, 73: 196-205.
[19] X Yan, D Zhang, F Zhao. Improve the signal to noise ratio and installation convenience of the inductive coil for wire rope nondestructive testing. NDT & E International, 2017, 92: 221-227.
[20] C Carlo, Z Daniele, L H Ait, et al. Calibration of elasto-magnetic sensors on in-service cable-stayed bridges for stress monitoring. Sensors, 2018, 18(2): 466.
[21] C F He, M Yang, X C Liu, et al. Characterisation of case depth in induction-hardened medium carbon steels based on magnetic minor hysteresis loop measurement technique. Philosophical Magazine, 2017: 1-16.