Effects on Radius of Curvature of Load Pad on Position Errors of Force Transducer

  • LIANG Wei ,
  • YANG Xiaoxiang ,
  • WANG Xiurong ,
  • YAO Jinhui
Expand
  • 1. School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou, 350116;
    2. Department of Intelligent Measurement, Metrology Institute of Fujian, Fuzhou, 350003;
    3. School of Applied Science&Technology, Quanzhou Normal University, Quanzhou, Fujian, 362000

Received date: 2018-03-09

  Revised date: 2019-06-12

  Online published: 2020-07-20

摘要

对不同接触形式的球头副的载荷偏心量和接触应力进行了分析,并设计了9对不同接触形式、不同结构尺寸的球头副进行方位误差测量。实验结果发现,相对于球面-球面点接触形式球头副,球面-平面点接触形式球头副的方位误差更小,球面-球面完全接触形式球头副与球面-平面点接触形式球头副的偏心载荷相当;调整角度较小时,可以选用球面-球面点接触或球面-球面完全接触,调整角度较大时,宜采用球面-平面点接触或半径较小的球面-球面完全接触。

本文引用格式

梁伟 , 杨晓翔 , 王秀荣 , 姚进辉 . 球头副曲率半径对力传感器方位误差的影响[J]. 中国机械工程, 2019 , 30(18) : 2198 -2206 . DOI: 10.3969/j.issn.1004-132X.2019.18.009

Abstract

Load eccentricity and contact stress of load pads with different contact forms were compared. 9 pieces of load pads with different structures were designed and tested.The experimental results show that the position errors of the sphere-plane contact are smaller than that of sphere-sphere point contact.Load eccentricities with sphere-sphere uniform contact and sphere-plane contact are similar. The sphere-sphere point contact and the sphere-sphere uniform contact are suitable for the situations when the angle of adjustment is small.The sphere-plane contact and the sphere-sphere uniform contact with small radius are used if the angle of adjustment is large.

参考文献

[1] KHALED K M, MAHMOUD G M. The Influence of the Unloading Rate on Creep Recovery of Force Transducers[J]. Measurement, 2018, 114(1):436-447.
[2] 雷成,肖守讷,罗世辉. 轨道车辆切削式吸能装置吸能特性研究[J]. 中国机械工程, 2013, 24(2):263-267. LEI Chen, XIAO Shoune, LUO Shihui. Research on Energy Absorption Characteristics of Rail Vehicle Energy-absorbing Component in Cutting Way[J]. China Mechanical Engineering, 2013, 24(2):263-267.
[3] KVHNEL M, HILBRUNNER F, BVCHNER H, et al. Traceable Measurement of Mechanical Parameters of Double Bending Beam Force Transducers According to EN ISO 376[J]. Measurement, 2014, 51(5):336-342.
[4] 张磊安,乌建中,陈州全,等. 兆瓦级风电叶片静力加载控制系统设计及试验[J]. 中国机械工程, 2011, 22(18):2182-2185. ZHANG Leian, WU Jianzhong, CHEN Zhouquan, et al. Design and Trial of MW Wind Turbine Blade Static Loading Control System[J]. China Mechanical Engineering, 2011, 22(18):2182-2185.
[5] MASTINU G, GOBBI M, PREVIATI G. A New Six-axis Load Cell[J]. Experimental Mechanics, 2011, 51(3):373-388.
[6] KUMAR R, MAJI S. Force Transducers:a Review of Design and Metrological Issues[J]. Engineering Solid Mechanics, 2016, 53(4):81-90.
[7] LIANG W, YANG X, YAO J. Rotation Effects of Force Transducer on the Output of the Build-up System[J]. Measurement, 2019, 138(5):659-671.
[8] 刘九卿. 圆柱、圆筒式称重传感器非线性和旋转误差分析[J]. 衡器, 2013, 42(3):1-7. LIU Jiuqing. Nonlinear and Rotating Error Analysis of Cylinder and Cylinder Type Weighing Sensor[J]. Weighing Instrument, 2013, 42(3):1-7.
[9] 池辉. 基于均力结构60 MN叠加式力值传递系统[J]. 计量学报, 2015, 36(2):221-224. CHI Hui. The 60 MN Build-up Force Delivery System Based on Compensating Structure[J]. Acta Metrologica Sinica, 2015, 36(2):221-224.
[10] TEGTMEIER F, ROSK D, LIANG W. Practical Applications of an Enhanced Uncertainty Model for Build-up Systems[C]//IMEKO 23rd Conference on the Measurement of Force, Mass and Torque Measurement. Helsinki, 2017:201-206.
[11] WAGNER M A, TSIPORENKO L, TEGTMEIER F.Development of a 15 MN Build-up System for Calibrations in Ukraine's Heavy Industry[C]//ⅩⅩⅠ IMEKO World Congress. Prague, 2015:22-26.
[12] JOHNSON K L. Contact Mechanics[M]. London:Cambridge University Press, 1985:56-61.
[13] International Organization for Standardization Technical Committee 164. ISO 376-2011 Metallic Materials-Calibration of Force Proving Instruments Used for the Verification of Uniaxial Testing Machines[S]. Geneva:ISO, 2011.