摘要

对某核电站稳压器电加热元件的包壳管变色原因进行了分析。结果表明:不锈钢包壳管长期暴露在高温环境中,其表面生成了均匀、致密的保护性氧化膜,氧化膜颗粒细小;变色包壳管材料不同部位的晶粒度均为6.5~7级,未出现晶粒异常长大的现象,非金属夹杂物和α相含量无异常;包壳管与端塞处焊缝未观察到裂纹。

Abstract

The discoloration reason of the cladding tube of the electrical heating element of a nuclear power plant regulator was analyzed. The results show that uniform and dense protective oxide film was formed on the surface of stainless steel cladding tube exposed to high temperature for a long time, and the oxide film particles were fine. The grain size of different parts of the discoloration cladding tube material was 6. 5~7 grade, and there was no abnormal grain growth, and there was no abnormal content of non-metallic inclusions and α phase. No cracks were observed in the weld between the cladding tube and the end plug.

关键词

稳压器 / 电加热元件 / 包壳管 / 变色

Key words

stabilizer / electric heating element / shell tube / discoloration

引用本文

导出引用
舒茗, 徐祺, 王浩, 赵兴保. 稳压器电加热元件包壳管变色原因[J]. 理化检验—物理分册, 2022, 58(4): 68-72 https://doi.org/10.11973/lhjy-wl202204018
SHU Ming, XU Qi, WANG Hao, ZHAO Xingbao. Causes for discoloration of electric heating component shell tube of regulator[J]. Physical Testing and Chemical Analysis Part A:Physical Testing, 2022, 58(4): 68-72 https://doi.org/10.11973/lhjy-wl202204018

参考文献

[1] 聂春福. 压水堆蒸汽式稳压器[J].核动力工程,1987,8(3):24-34.
[2] 张婷.浅谈核岛稳压器[J].科技创新与应用,2013(24):300.
[3] 许维钧,马春来,沙仁礼.核工业中的腐蚀与防护[M].北京:化学工业出版社,1993.
[4] 原瑜,王天先,王文利,等.Z2CND17-12不锈钢自动脉冲TIG焊性能试验[J].电焊机,2018,48(8):92-95,103.
PDF(4930 KB)

268

Accesses

0

Citation

Detail

段落导航
相关文章

/